Lablisa® FastTrack Human Cys-C(CystatinC) ELISA Kit

Product Information

Lablisa® FastTrack Human Cys-C(CystatinC) ELISA Kit

Catalog No : LAB005FT | Pack Size : 48T , 96T

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Cys-C, and the Human Cys-C standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human Cys-C. After TMB substrate solution is added, only those wells that contain Human Cys-C and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Cys-C in the samples is then determined by comparing the OD of the samples to the standard curve.

Product name:Lablisa® FastTrack Human Cys-C(CystatinC) ELISA Kit
Reactivity:Human
Alternative Names:CST3; Cystatin 3; ARMD11; Post-Gamma-Globulin
Assay Type:Sandwich
Sensitivity:25 pg/mL
Standard:5000 pg/mL
Detection Range:78.1-5000 pg/mL
Sample Type:Serum, plasma
Assay Length:1.5h
Research Area:Tags & Cell Markers;Cell Biology;Stem Cells;Cardiovascular

Standard curve



Concentration (pg/mL)ODCorrected OD
5000.002.7812.716
2500.001.7011.637
1250.000.9060.842
625.000.5080.443
312.500.3190.254
156.250.1770.113
78.130.1200.056
0.000.064

0.000


Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant Cys-C and the recovery rates were calculated by comparing the measured value to the expected amount of Cys-C in samples.

MatrixRecovery rangeAverage
serum(n=5)88-99%94%
EDTA plasma(n=5)102-110%104%
Heparin plasma(n=5)98-104%101%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cys-C and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=5)93-106%88-102%85-101%96-107%
EDTA plasma(n=5)90-103%94-108%90-106%98-105%
Heparin plasma(n=5)91-100%98-107%92-108%93-102%