Lablisa® Dog Testo(Testosterone) ELISA Kit

Product Information

Lablisa® Dog Testo(Testosterone) ELISA Kit

Catalog No : LAB0621 | Pack Size : 48T , 96T

This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Dog Testo protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Dog Testo. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Dog Testo in the samples is then determined by comparing the OD of the samples to the standard curve.

Product name:Dog Testo(Testosterone) ELISA Kit
Reactivity:Dog
Alternative Names:T; Testesteron; Testeronun
Assay Type:Competitive Inhibition
Sensitivity:0.17 ng/mL
Standard:20 ng/mL
Detection Range:0.31-20 ng/mL
Sample Type:serum, plasma, other biological fluids
Assay Length:2.5h
Research Area:Endocrinology;Reproductive science;Hormone metabolism;


Standard curve



Concentration (ng/mL)ODCorrected OD
20.000.199
10.000.332
5.000.611
2.500.861
1.251.253
0.631.596
0.321.871
0.00
2.211


Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant Testo and the recovery rates were calculated by comparing the measured value to the expected amount of Testo in samples.

MatrixRecovery rangeAverage
serum(n=5)95-107%101%
EDTA plasma(n=5)78-92%85%
Heparin plasma(n=5)80-97%88%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Testo and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=5)95-102%93-101%81-89%85-99%
EDTA plasma(n=5)95-107%87-102%85-96%95-104%
Heparin plasma(n=5)82-90%89-102%97-103%88-96%


Manuals on the web are for your reference only, specifications are subject to the delivery manuals.