Lablisa® Human BMG/b2-MG(Beta-2-Microglobulin) ELISA Kit

Product Information

Lablisa® Human BMG/b2-MG(Beta-2-Microglobulin) ELISA Kit

Catalog No : LAB1200| Pack Size : 48T , 96T

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human BMG/b2-MG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human BMG/b2-MG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human BMG/b2-MG, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human BMG/b2-MG in the samples is then determined by comparing the OD of the samples to the standard curve.

Product name:Human BMG/b2-MG(Beta-2-Microglobulin) ELISA Kit
Reactivity:Human
Alternative Names:Beta 2M; BMG; B2MG; b2M; Beta-2-Microglobulin
Assay Type:Sandwich
Sensitivity:0.16 ng/mL
Standard:25 ng/mL
Detection Range:0.4-25 ng/mL
Sample Type:serum, plasma, urine and other biological fluids
Assay Length:3.5h
Research Area:Infection immunity;Kidney biomarker;


Standard curve



Concentration (ng/mL)ODCorrected OD
25.002.2012.117
12.501.5931.509
6.251.1211.037
3.130.8920.808
1.570.5470.463
0.790.3450.261
0.400.2650.181
0.000.0840.000


Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant BMG/b2-MG and the recovery rates were calculated by comparing the measured value to the expected amount of BMG/b2-MG in samples.

MatrixRecovery rangeAverage
serum(n=5)78-91%84%
EDTA plasma(n=5)88-101%94%
Heparin plasma(n=5)82-95%88%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BMG/b2-MG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=5)88-105%79-93%87-98%85-96%
EDTA plasma(n=5)88-97%97-105%81-93%89-102%
Heparin plasma(n=5)88-102%81-96%86-93%82-95%