Lablisa® 5-HIAA(5-Hydroxyindoleacetic Acid) ELISA Kit
Product Information
- Description
- More Infomation
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with 5-HIAA. Standards or samples are added to the appropriate micro ELISA plate wells then with a biotin-conjugated antibody specific to 5-HIAA. Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of 5-HIAA in the samples is then determined by comparing the OD of the samples to the standard curve.
Product name: | Lablisa® 5-HIAA(5-Hydroxyindoleacetic Acid) ELISA Kit |
Reactivity: | Universal |
Alternative Names: | 5HIAA |
Assay Type: | Competitive |
Sensitivity: | 1.93 ng/mL |
Standard: | 400 ng/mL |
Range: | 6.25-400 ng/mL |
Sample Type: | Serum, Plasma, urine, cerebrospinal fluid and Other biological fluids |
Assay Length: | 1.5h |
Research Area: | Metabolic pathway;Tumor immunity;Endocrinology;Urology; |
Standard curve
Concentration (ng/mL) | OD |
---|---|
400.00 | 0.261 |
200.00 | 0.424 |
100.00 | 0.664 |
50.00 | 0.981 |
25.00 | 1.274 |
12.50 | 1.594 |
6.25 | 1.864 |
0.00 | 2.686 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
Recovery
The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Matrix | Recovery range | Average |
---|---|---|
serum(n=8) | 85-97% | 91% |
EDTA plasma(n=8) | 85-97% | 91% |
Cell culture media (n=8) | 83-99% | 95% |
Linearity
Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 87-98% | 85-92% | 80-96% | 89-100% |
EDTA plasma(n=5) | 91-102% | 91-102% | 89-97% | 86-102% |
Cell culture media (n=5) | 94-106% | 81-97% | 88-102% | 85-93% |