Catalog No : LAB088FT | Pack Size : 48T , 96T

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VE-Cadherin, and the Human VE-Cadherin standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human VE-Cadherin. After TMB substrate solution is added, only those wells that contain Human VE-Cadherin and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VE-Cadherin in the samples is then determined by comparing the OD of the samples to the standard curve.

Product name:Lablisa® FastTrack Human VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit
Reactivity:Human
Alternative Names:CD144; 7B4; Cadherin 5 Type 2; VE-Cadherin; Cadherin,Vascular Endothelial; CDH5; Cadherin 5
Assay Type:Sandwich
Sensitivity:32.1 ng/mL
Standard:10 μg/mL
Detection Range:0.16-10 μg/mL
Sample Type:Serum, plasma
Assay Length:1.5h
Research Area:CD & Adhesion molecule;Tumor immunity;Infection immunity;

Standard curve



Concentration (μg/mL)ODCorrected OD
10.002.0751.987
5.001.6081.520
2.501.2051.117
1.250.8520.764
0.630.5140.426
0.320.3170.229
0.160.2520.164
0.000.0880.000


Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant VE-Cadherin and the recovery rates were calculated by comparing the measured value to the expected amount of VE-Cadherin in samples.

MatrixRecovery rangeAverage
serum(n=5)85-97%91%
EDTA plasma(n=5)80-95%87%
Heparin plasma(n=5)89-103%96%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VE-Cadherin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=5)87-98%92-105%95-107%82-96%
EDTA plasma(n=5)88-97%86-92%94-103%89-97%
Heparin plasma(n=5)96-105%87-96%90-98%92-101%