Lablisa® FastTrack Human NT-ProBNP (N-Terminal Pro-Brain Natriuretic Peptide) ELISA Kit

Product Information

Lablisa® FastTrack Human NT-ProBNP (N-Terminal Pro-Brain Natriuretic Peptide) ELISA Kit

Catalog No : LAB035FT | Pack Size : 48T , 96T

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human NT-ProBNP, and the Human NT-ProBNP standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human NT-ProBNP. After TMB substrate solution is added, only those wells that contain Human NT-ProBNP and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NT-ProBNP in the samples is then determined by comparing the OD of the samples to the standard curve.

Product name:Lablisa® FastTrack Human NT-ProBNP (N-Terminal Pro-Brain Natriuretic Peptide) ELISA Kit
Reactivity:Human
Alternative Names:NT-Pro-BNP; N-BNP; ANFB_HUMAN; BNP(1-32); BNP(5-29); BNP-32; Gamma-brain natriuretic peptide; nppb
Assay Type:Sandwich
Sensitivity:0.94 ng/mL
Standard:60 ng/mL
Detection Range:0.94-60 ng/mL
Sample Type:Serum, plasma
Assay Length:1.5h
Research Area:Endocrinology;Cardiovascular biology;

Standard curve



Concentration (ng/mL)ODCorrected OD
60.002.2072.106
30.001.6431.542
15.001.2511.150
7.500.8470.746
3.750.6250.524
1.880.3010.200
0.940.2880.187
0.000.1010.000


Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant NT-ProBNP and the recovery rates were calculated by comparing the measured value to the expected amount of NT-ProBNP in samples.

MatrixRecovery rangeAverage
serum(n=5)90-103%96%
EDTA plasma(n=5)81-96%88%
Heparin plasma(n=5)78-94%86%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NT-ProBNP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=5)89-98%83-103%98-105%92-101%
EDTA plasma(n=5)96-101%85-92%79-96%89-101%
Heparin plasma(n=5)93-105%85-97%90-99%82-101%