Lablisa® Human FN(Fibronectin) ELISA Kit
![Lablisa® Human FN(Fibronectin) ELISA Kit](https://www.labrecon.in/upload/product/1.cMroKn.jpg)
![](https://www.labrecon.in/upload/product/1.cMroKn.jpg)
Product Information
- Description
- More Infomation
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FN in the samples is then determined by comparing the OD of the samples to the standard curve.
Product name: | Human FN(Fibronectin) ELISA Kit |
Reactivity: | Human |
Alternative Names: | FN1; CIG; FINC; LETS; MSF; GFND2; Anastellin; Migration-Stimulating Factor; Cold-Insoluble Globulin; Large, External, Transformation-Sensitive Protein |
Assay Type: | Sandwich |
Sensitivity: | 0.69 ng/mL |
Standard: | 100 ng/mL |
Detection Range: | 1.57-100 ng/mL |
Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Signal transduction;Infection immunity; |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
100.00 | 1.908 | 1.812 |
50.00 | 1.412 | 1.316 |
25.00 | 1.027 | 0.931 |
12.50 | 0.752 | 0.656 |
6.25 | 0.438 | 0.342 |
3.13 | 0.262 | 0.166 |
1.57 | 0.174 | 0.078 |
0.00 | 0.096 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant FN and the recovery rates were calculated by comparing the measured value to the expected amount of FN in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 81-95% | 88% |
EDTA plasma(n=5) | 92-107% | 99% |
Heparin plasma(n=5) | 85-98% | 91% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 95-102% | 89-96% | 87-98% | 85-93% |
EDTA plasma(n=5) | 91-103% | 86-92% | 88-97% | 89-97% |
Heparin plasma(n=5) | 79-94% | 87-96% | 78-93% | 82-90% |